{"id":6025,"date":"2020-03-04T08:33:35","date_gmt":"2020-03-04T08:33:35","guid":{"rendered":"https:\/\/www.cafmet-conference.com\/en\/?page_id=6025"},"modified":"2022-05-06T08:25:01","modified_gmt":"2022-05-06T08:25:01","slug":"atelier-carlossimoes2","status":"publish","type":"page","link":"https:\/\/www.cafmet-conference.com\/en\/atelier-carlossimoes2\/","title":{"rendered":"Atelier : Pipettes Calibration Automation"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"6025\" class=\"elementor elementor-6025\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-25a5abd elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"25a5abd\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-73b4bc7\" data-id=\"73b4bc7\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-55d1880 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"55d1880\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-5ef13d2\" data-id=\"5ef13d2\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-158212c elementor-widget elementor-widget-text-editor\" data-id=\"158212c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<h3>Programme :<\/h3><p>Volumetric instruments are essential for any laboratory or industry that want a correct volume measurement, which can have a great influence on the end result of a test<br \/>where volume measurement is only a small component of a series of experimental steps. The calibration of volumetric instruments, in particular pipettes, aims the quantification of differences between the nominal value and the real value, and from the<br \/>metrological point of view of great interest, once that it contributes to the understanding of the systematic errors of the analytical measurement process, as well as to give the possibility to proceed to its correction.<br \/>We need to understand the differences between the interventions in micropipettes:<br \/>\u2192 Pipette Performance Test: it compares the accuracy and precision of a pipette with defined tolerances and typically is performed every quarter.<br \/>\u2192 Pipette Calibration: A calibration includes an additional physical<br \/>inspection and, if needed, adjustment or repair. This is carried out normally<br \/>once to twice a year.<br \/>Costumer compliance with regulations such as GLP\/GMP or ISO, the calibration frequency depends on the pipette use and should be defined under a risk analysis approach. In non-regulated market, customers basically need reproducible measurements and the calibration frequency is defined so that errors are avoided in order to quickly publish reliable results. Trescal has the right solution depending on our clients specifications defined for this type of equipment.<\/p><h3>Pr\u00e9-requis :\u00a0<\/h3><div><ul style=\"list-style-type: circle;\"><li>Know how to use pipettes.<\/li><\/ul><h3>Keywords<\/h3><p>Micropipette, Calibration, ISO 8655, Compliance.<\/p><\/div><h3>Langue :\u00a0 Anglais<\/h3><h3>Dur\u00e9e : 4<strong> heures &#8211; Matin<\/strong><\/h3><h3>Date : 19\/05\/2022<\/h3><h3>Lieu : SOFITEL Tour Blanche, Rue Sidi Belyout, 20 000 \u2013 Casablanca, MOROCCO<\/h3>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-2a9f45d\" data-id=\"2a9f45d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4e31bfa elementor-widget elementor-widget-text-editor\" data-id=\"4e31bfa\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<h3>Animateur : Carlos SIMOES<\/h3>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-979aee9 elementor-widget elementor-widget-image\" data-id=\"979aee9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/www.cafmet-conference.com\/wp-content\/uploads\/2022\/04\/Carlos-SIMOES.jpg\" class=\"attachment-medium size-medium wp-image-7959\" alt=\"\" srcset=\"https:\/\/www.cafmet-conference.com\/wp-content\/uploads\/2022\/04\/Carlos-SIMOES.jpg 200w, https:\/\/www.cafmet-conference.com\/wp-content\/uploads\/2022\/04\/Carlos-SIMOES-150x150.jpg 150w, https:\/\/www.cafmet-conference.com\/wp-content\/uploads\/2022\/04\/Carlos-SIMOES-12x12.jpg 12w\" sizes=\"(max-width: 200px) 100vw, 200px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0615db1 elementor-widget elementor-widget-text-editor\" data-id=\"0615db1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>Carlors SIMOES<\/strong>\u00a0est actuellement directeur technique de TRESCAL et repr\u00e9sentant du Groupe TRESCAL en Espagne et au Portugal.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Programme : Volumetric instruments are essential for any laboratory or industry that want a correct volume measurement, which can have a great influence on the end result of a test &#8230;<\/p>","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6025","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.cafmet-conference.com\/en\/wp-json\/wp\/v2\/pages\/6025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cafmet-conference.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.cafmet-conference.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.cafmet-conference.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cafmet-conference.com\/en\/wp-json\/wp\/v2\/comments?post=6025"}],"version-history":[{"count":0,"href":"https:\/\/www.cafmet-conference.com\/en\/wp-json\/wp\/v2\/pages\/6025\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.cafmet-conference.com\/en\/wp-json\/wp\/v2\/media?parent=6025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}